Countertop Warming and display
OperatOrs Manual
4
troUbleShooting chart
Problem It might be caused by Course of Action
No Water in the wells.
Check to make sure there is power supplied to
the Auto-ll unit.
Verify the switch is ON. Verify the water supply valve is open.
Refer to the installation section and be sure all steps were followed
properly.
Wells are not getting hot enough. There may be too much water in the wells. Change the water level to a maximum depth of 3/8”.
No Water in the wells. The reservoir assembly may be set too low. Loosen the fasteners and raise the assembly.
The water continues to run and the
water ows out the over ow tube.
There may be a clog in the drain assembly
preventing water from reaching the oat or the
drain overow may be clogged causing an air
lock in the Auto-Fill reservoir.
Make sure drain line is open and water is able to reach the
reservoir. Also, make sure the auto ll system is plugged in and
grounded.
The wells continue to ll beyond
the desired water level.
The oat switch may be installed incorrectly.
Disconnect power and remove the control box cover on the outside
of the revisor tank. Check to see that the arrow molded into the
white plastic nut portion of the oat switch is pointing DOWN.
Service and repair
There are no user serviceable parts within this appliance. To avoid serious injury or damage, never attempt to repair the equipment or replace a damaged power
cord yourself. Do not send equipment directly to the Vollrath Company. Please contact the qualied professional repair service listed below.
VOLLRATH Technical Service • 1-800-628-0832
operation
WARNING
Electrical Shock Hazard.
Keep water and other liquids from entering the
inside of the equipment.
Liquid could contact the
electrical components and cause a short circuit
or an electrical shock. Do not spray water or
cleaning products. Do not use equipment if power
cord is damaged or has been modied.
1. Check the drain valve of the Hot Food Unit. Make sure it is in the closed
position to prevent water from draining out. Generally, the valve is in the
off position when the handle of the valve forms a “T” with the body of the
valve.
2. Turn Auto-Fill control on. Operate the Vollrath Hot Food Table in
accordance with the Operating and Safety Instructions that were
provided with the Hot Food Table.
3. At the end of the serving period, turn the Auto-ll control off before
opening the drain valve for the Hot Food Unit. If the unit is drained with
the Auto-ll on, the unit will continue to ll and will not completely drain.
4. Follow the shut down and cleaning procedures that were sent with the
Hot Food Table. No special cleaning is required for the Auto-ll system.